Technology · NEMOW UTD

Developing an intrauterine vacuum-based device concept.

Explore the investigational NEMOW Uterine Toner Device (UTD) concept and its described components.

Explore the deviceSelect a component in the gallery to bring its illustration and summary into focus.
NEMOW UTD Device, complete product view
Selected viewComplete UTD DeviceProduct overview · select a component below
Device overview

Designed around key functional elements.

NEMOW UTD is an investigational medical technology concept. Its described elements include a conical insertion tip, upper evacuation openings, a cervical portion seal and balloon, a pilot balloon with spring-loaded valve, and a lower suction connector.

Component-focused layout
Distinct elements support clear visual identification.
Connection-oriented design
A lower connector is intended for standard suction equipment integration.
Adjustable balloon element
The cervical portion includes a balloon with an inflation control element.
Investigational device notice

Clinical evaluation is essential.

NEMOW UTD is investigational. Its safety and effectiveness have not been established by this website content. It is not a replacement for standard care and should not be described as approved or cleared unless authorized by the relevant regulator.

Explore each component

Designed as a system. Understood piece by piece.

Explore the visible construction, intended role and key design notes for each named element. Select “Focus in viewer” to bring its supplied product image into the large showcase above.

COMPONENT / 01Product detail of the green conical insertion tip

Green Conical Tip

01

A tapered, teal-green leading end that is visually distinct from the transparent body.

INTENDED ROLE

Described as supporting smooth and easy insertion.

DESIGN NOTE

The contrasting tip makes the leading end easy to identify in the product view. Handling and insertion must follow approved instructions for use.

COMPONENT / 02Product detail of upper evacuation openings

Upper Evacuation Openings 4 mm & 5 mm

02

Multiple openings positioned along the upper transparent section of the device.

INTENDED ROLE

The supplied description identifies the openings as intended for blood/clot clearance and uterine wall approximation.

DESIGN NOTE

The component name references 4 mm and 5 mm openings. Confirm dimensions and technical characteristics against controlled product specifications.

COMPONENT / 03Product detail of the cervical portion seal and balloon

Cervical Portion Seal & Balloon

03

A wider, flexible-looking section around the device body, shown as part of the seal and balloon assembly.

INTENDED ROLE

Described as supporting secure cervical sealing with adjustable inflation.

DESIGN NOTE

Inflation is described as adjustable, but operating volume, pressure and technique are not specified on this page. Refer to approved device documentation.

COMPONENT / 04Product detail of the pilot balloon and spring-loaded valve

Pilot Balloon & Spring-Loaded Valve

04

A separate pilot balloon and valve assembly connected to the main device by a small line.

INTENDED ROLE

The supplied description identifies this assembly as supporting controlled pressure maintenance.

DESIGN NOTE

The photograph is for component recognition only; it does not define a pressure target or show an operating procedure.

COMPONENT / 05Product detail of the lower suction connector

Lower Suction Connector

05

The teal connector at the lower end of the pictured device assembly.

INTENDED ROLE

Described as the interface for integration with standard suction equipment.

DESIGN NOTE

Equipment fit and operating requirements should be confirmed from the official compatibility and use documentation.

Explore partnership opportunities

For professional, clinical, technical or partnership inquiries, connect directly with the NEMOW team.

Contact NEMOW
Important: The product visuals on this page are for general information and visual identification only; they are not engineering drawings or clinical instructions. Device use, safety, performance and indications must be confirmed from official product documentation and applicable regulatory information. This website is not medical advice.